TVS Selection: Standoff, Clamp, Current, Capacitance
A TVS is chosen by four numbers and the order matters. Get the standoff wrong and it conducts in normal operation; get the clamp wrong and it protects nothing.
Quick Answer
- VRWM (standoff) must be above the maximum continuous voltage, including tolerance and ripple.
- VC (clamp) at your surge current must be below the protected IC's absolute maximum.
- IPP must exceed the surge current for the standard you are testing to.
- Capacitance must fit the signal: hundreds of pF on power, under a few pF on high-speed data.
1. The four numbers
| Parameter | Rule | Failure if wrong |
|---|---|---|
| VRWM | Above rail max, with margin | Leaks or conducts in normal use |
| VBR | Above VRWM; sets conduction point | Clamps too early or too late |
| VC at IPP | Below IC absolute maximum | IC dies with the TVS intact |
| C | Fits the signal budget | Eye closure on high-speed links |
2. Clamp voltage is a curve, not a number
VCL(I) ~ VBR + Rd x I Example: 8 kV ESD contact -> about 24 A VBR 6.1 V, Rd 1 ohm -> VCL ~ 30 V at the part
That is why "clamping voltage 12 V" on a datasheet does not mean the IC sees 12 V during an 8 kV strike. The IC sees the clamp plus the inductive drop of the trace between them — which is the argument for placing the TVS at the connector.
Dynamic resistance is the useful figure for extrapolation. A part with 0.5 Ω adds 12 V at 24 A; a part with 1.5 Ω adds 36 V. Two parts with the same headline clamp can behave very differently under a real strike.
3. Pick the standard first
| Test | Typical level | TVS characteristic |
|---|---|---|
| ESD (61000-4-2) | ±8 kV contact | Fast response, low capacitance |
| EFT (61000-4-4) | ±2 kV bursts | Repeated pulses, thermal |
| Surge (61000-4-5) | 0.5–4 kV | High energy, larger package |
4. A worked selection
5 V rail with ±5 % tolerance and 100 mV ripple: maximum continuous is about 5.35 V. Choose a part with VRWM at least 5.5–6 V. The protected IC has an absolute maximum of 6.5 V; the TVS must clamp below that at the expected surge current, which for ESD means checking the curve at 20–30 A, not at 1 A.
That combination is often impossible with a small SMD TVS at 5 V: the clamp at 24 A may be 15–20 V, far above the 6.5 V absolute maximum. The realistic answer is that the TVS limits the energy and the IC's own ESD structure handles the residual — which is why system-level testing matters more than the datasheet arithmetic.
A second example, 24 V industrial input: maximum continuous maybe 26.4 V with tolerance. Choose VRWM 26–28 V, and check the clamp at the surge current for your test level — a 4 kV surge can push tens of amps, and the resulting clamp may exceed the downstream regulator's 40 V rating. That is the case for a two-stage design: a high-energy part at the connector plus a lower-clamp part after a series impedance.
| Rail | Typical VRWM | Watch |
|---|---|---|
| 3.3 V | 3.6–5 V | Low clamp vs 3.3 V IC abs max |
| 5 V | 5.5–6.5 V | Tolerance + ripple can reach VRWM |
| 12 V | 13–15 V | Load dump if automotive |
| 24 V | 26–30 V | Clamp vs regulator rating |
5. TVS versus the alternatives
A varistor absorbs more energy but is slower and capacitive; a zener clamps precisely but handles little energy; a polymer suppressor is small and fast but limited. For a power input, a TVS plus a fuse or eFuse is the usual combination; for high-speed data, a low-capacitance array.
6. Layout
- Place the TVS at the connector, before any series element.
- Ground with short, wide copper and multiple vias — not a thin trace.
- Keep the protected trace short; every millimetre adds inductance.
- Do not route the surge path through the IC's ground.
For the pin-level layout of a USB port, the USBLC6 ESD guide walks through the same placement with numbers.
6b. Selection checklist
| Step | Pass |
|---|---|
| VRWM | Above rail maximum with margin |
| Clamp at test current | Below IC absolute maximum |
| Peak pulse power | Above the standard's level |
| Capacitance | Within the signal budget |
| Leakage | Below the system's standby allowance |
| Layout | At connector, short ground |
7. FAQ
Can one TVS protect both power and data?
Rarely well. Power needs energy handling; data needs low capacitance. Use an array for data and a separate part for the rail.
Why does my 5 V TVS conduct at 5 V?
VRWM is a standoff, not a clamp. A part rated 5 V may start conducting near 6 V, and a rail with tolerance can reach it. Choose the next voltage up.
Is a lower clamp always better?
Not if it costs capacitance or energy handling. Match the clamp to the IC's absolute maximum, not to the lowest number available.
Do I need a fuse with a TVS?
For a power input, usually yes. The TVS clamps the transient; the fuse or eFuse limits the follow-on current.
How do I test it?
System-level IEC tests at the connector, with the cable and enclosure. Device-level ratings do not guarantee system results.
What is peak pulse power?
It is the short-duration power the part can absorb, usually specified with an 8/20 µs waveform. It is not the same as continuous dissipation; read the derating curve.
Does capacitance matter on a slow signal?
Only if the source impedance is high. On a 100 kHz I2C bus with 4.7 kΩ pull-ups, a few hundred pF is already visible.
8. Sources
- IEC 61000-4-2 / -4-4 / -4-5 — ESD, EFT and surge test standards.
- TVS datasheets — VRWM, VBR, VC at IPP, capacitance, peak pulse power.
- Application notes on TVS selection and layout (Littelfuse, Bourns, ON Semiconductor).
Choosing a TVS?
Send the rail voltage, the standard you must pass and the signal rate. We will narrow it to a part and a placement.