Decoupling Capacitor Selection: Dielectric, Bias, and Distance
A 10 µF capacitor is not 10 µF. At rated voltage it may be half that, and above its self-resonant frequency it is an inductor. The three numbers that matter are not on the front page.
Quick Answer
- Dielectric: X7R for decoupling, C0G for filters and timing, X5R only when the bias is low.
- DC bias: a 10 µF X5R at 25 V can lose 60–80 % of its capacitance.
- Self-resonance: 100 nF 0402 resonates near 25 MHz; above that it is inductive.
- Distance: 1 nH per mm. Five millimetres is a different component.
1. Dielectrics are not interchangeable
| Class | Stability | Use |
|---|---|---|
| C0G / NP0 | Excellent, no bias loss | Filters, oscillators, timing |
| X7R | ±15 % over temperature | General decoupling |
| X5R | ±15 %, worse bias | Bulk where space is tight |
| Y5V | −80 % over temperature | Avoid for anything critical |
The same nominal value in C0G and Y5V can differ by a factor of five in circuit. The price difference is small; the design consequence is not.
| Case | Nominal | In circuit (estimate) |
|---|---|---|
| 10 µF X5R 25 V at 12 V | 10 µF | 4–5 µF |
| 10 µF X7R 16 V at 12 V | 10 µF | 5–6 µF |
| 10 µF C0G 25 V at 12 V | 10 µF | 10 µF (larger case) |
2. DC bias: the hidden derating
This is the most common reason a decoupling network that looks generous on paper is marginal in circuit. A 10 µF X5R 25 V part at 12 V may measure 4 µF; a 10 µF X7R 16 V at 12 V may measure 5 µF. The datasheet value is measured at 0 V.
Practical consequence: for a rail within 50 % of the capacitor's rating, assume 50 % of the nominal value unless the vendor publishes a bias curve. For C0G, use the nominal value.
3. Above self-resonance it is an inductor
SRF = 1 / (2 pi sqrt(L x C)) 100 nF, 0.4 nH (0402): 25 MHz 1 uF, 0.8 nH: 5.6 MHz 10 nF, 0.8 nH: 56 MHz
Below SRF the impedance falls with frequency; above it, the ESL sets the impedance and rises. That is why a 1 µF part does not replace a 100 nF part at high frequency, and why the small capacitor should be closest to the pin.
Two capacitors in parallel do not simply add: between their self-resonant frequencies the pair can show a local impedance rise (anti-resonance), which is why a small C0G next to the pin and a larger X7R nearby is a better pair than two identical parts. The exact shape depends on ESR, which damps the peak.
4. Distance is inductance
The capacitor supplies the current the regulator cannot respond to, and the trace between them is an inductor in series with that supply. The rule is placement first, value second: a 100 nF at the pin beats a 10 µF at the far end of the board for high-frequency transients.
Vias are part of the distance. A single via to the ground plane adds roughly 0.5–1 nH; two parallel vias halve that. For a high-current rail, the return path through the plane matters as much as the capacitor value.
5. Pick by role
| Role | Typical | Mistake |
|---|---|---|
| Bulk input | 10–100 µF, low ESR | Using a tiny case for a large value |
| Local decoupling | 100 nF, 0402/0603 | Placed 10 mm away |
| High frequency | 10–100 nF, C0G | Using X5R for a filter |
| Analog reference | 1–10 µF, low leakage | High-leakage electrolytic |
For switching converters, the input capacitor also carries ripple current; see the buck layout guide for that calculation. For the SPI and I²C side, the flash layout guide shows the same placement logic at a different frequency.
5b. A practical default
| Rail | Default network |
|---|---|
| 3.3 V logic, low current | 100 nF per pin, 10 µF per rail |
| 5 V logic, mixed loads | 100 nF per pin, 22 µF per rail |
| Switching converter input | 10 µF ceramic close, plus bulk |
| Analog reference | 1 µF C0G or low-leakage, close |
6. Checklist
- Choose the dielectric by role, not by price.
- Check the DC-bias curve at the working voltage.
- Check the SRF against the frequencies you need to decouple.
- Place the smallest capacitor closest to the pin.
- Add vias to the ground plane, one per capacitor minimum.
- For large values, check ripple current and case size.
7. FAQ
Is a bigger capacitor always better?
No. Larger values have more ESL and lower SRF, and they do not replace a small capacitor at high frequency.
Why does my 10 µF measure 4 µF?
DC bias. Class II ceramics lose capacitance as the voltage approaches the rating. C0G does not.
Can I use one capacitor for everything?
Not well. Bulk, local and high-frequency roles have different requirements.
Does capacitor aging matter?
For class II ceramics, capacitance drifts slowly with time and is restored by soldering heat. For precision timing, use C0G.
How close is close enough?
Within a few millimetres for the local decoupling capacitor, with a short return to the plane. If in doubt, move it closer.
Do I need a capacitor on every power pin?
Usually yes, one small capacitor per pin, plus the bulk capacitor shared by the rail.
8. Sources
- Manufacturer ceramic capacitor datasheets — DC-bias curves, temperature coefficients, ESR/ESL.
- Application notes on decoupling and PDN design (TI, Analog Devices, Murata, TDK).
- JEDEC/IPC component and assembly standards for package and mounting context.
Choosing decoupling capacitors?
Send the rail voltage, the noise frequency and the package. We will suggest a dielectric and a placement that actually works.